ABC Type Fire Extinguishers

Technical Specifications

Capacity(Kg)

:

1,2,4,6 & 9

Conforming IS Code

:

IS 15683

Type  of Extinguisher

:

Constant Pressure

Expellant

:

Pressurized with N2 gas/ Gas Cartridge

Minimum Effective Discharge

:

85%

Discharge Time (Secs.)

:

More than 8 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

-200C to +550C

Operating Valve 

:

Squeeze grip type  with discharge hose & nozzle

Clean Agent Type Fire Extinguisher

 
 
 
 

Technical Specifications

Capacity(Kg)

:

2,4 & 6

Conforming IS Code

:

IS 15683

Type  of Extinguisher

:

Constant Pressure

Type of Extinguish Media

:

Clean Agent Gas

Expellant

:

Pressurized with N2 gas

Minimum Effective Discharge

:

90 to 95%

Discharge Time (Secs.)

:

More than 13 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

-200C to +550C

Operating Valve 

:

Squeeze grip type  with discharge hose & nozzle


Application: Class- A Fire, Class- B Fire, Class- C Fire as   well as electrical fires

Clean agent

CO2 Type Fire Extinguishers

 
 
 
 

Technical Specifications

Capacity(Kg)

:

2,3 & 4.5/6.5,9 & 22.5

Conforming IS Code

:

IS 15683 / As Per IS:2878

Filling Ratio

:

0.667

Type of Extinguisher

:

CO2

Type of Extinguish Media

:

CO2

Minimum Effective Discharge

:

95%

Discharge Time (Secs.)

:

More than 08 Secs. /30 to 40 Secs.

Operating Temperature

:

-200C to +550C

Operating Valve 

:

Wheel /Squeeze grip type with discharge hose & horn


Application: Class- B & Class-C Fire 

Foam Type Fire Extinguisher

 
 
 
 

Technical Specifications

Capacity(Kg)

:

6 & 9

Conforming IS Code

:

IS 15683

Type  of Extinguisher

:

Constant Pressure

Type of Extinguish Media

:

AFFF IS 4989

Expellant

:

Pressurized with N2 gas/ Gas Cartridge

Minimum Effective Discharge

:

85%

Discharge Time (Secs.)

:

More than 13 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

+50C to +550C

Operating Valve 

:

Squeeze grip type  with discharge hose & nozzle


Application: Class- A, Class- B Fire 

k TYPE IMAGE

K Type Fire Extinguisher

                                
 
 
 

Technical Specifications

Capacity(Kg)

:

1,2,4,6 & 9

Chemical  Charge

:

Wet Chemicals

Minimum Effective Discharge

:

More  than 90%

Discharge Time (Secs.)

:

More than 8 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

+50C to +550C

Operating Valve 

:

Squeeze grip type  with discharge hose & nozzle


Application:
Class- K Fire: Cooking Oils, Vegetable/Animal Oils & Fat Fire
Also can be used for  Class-A Fire             

Modular/Ceiling Type

 
 
 
 

Technical Specifications

Capacity(Kg)

:

2,4 ,5, 6, 10 & 15

Type of Extinguish Media

:

ABC Dry  powder, Clean Agent / BC P:owder

Minimum Effective Discharge

:

85%

Mounting

:

Ceiling Mounting Type

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

Automatically at 57/68/93/107& 1430C                 

Effective Range

:

A, B, C and Electrically Started Fires


Application: Class- A Fire, Class- B Fire, Class- C Fire as   well as electrical fires

MODULAR IMAGE

Trolley Type Fire Extinguisher

 
 
 
 

Technical Specifications

Capacity(Kg)                                 

:

25,   50, 75Kgs./  50, 100, 200Ltrs.

Type  of Extinguisher

:

ABC/BC/Water/Foam Type

Type  of Extinguish Media

:

Dry Powder/Water/AFFF Foam

Expellant

:

Pressurized with N2 gas/ Co2 Cartridge & Cylinder

Minimum Effective Discharge

:

85%

Discharge Time (Secs.)

:

More than 40 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

-200C to +550C (Powder)/+50C to +550C (water/foam)

Operating Valve 

:

Rotate Type


Application: Class- A, Class- B,   Class- C Fire as well as Electrical Fires.

Water Type Fire Extinguisher

 
 
 
 

Technical Specifications

Capacity(Kg)

:

6 & 9

Conforming IS Code

:

IS 15683

Type  of Extinguisher

:

Constant Pressure

Type of Extinguish Media

:

Soft Water

Expellant

:

Pressurized with N2 gas/ Gas Cartridge

Minimum Effective Discharge

:

95%

Discharge Time (Secs.)

:

More than 13 Secs.

Hydraulic Test Pressure

:

35 Kg/Cm2

Charged Pressure

:

15 Kg/Cm2

Operating Temperature

:

+50C to +550C

Operating Valve 

:

Squeeze grip type  with discharge hose & nozzle


Application: Class- A Fire